By Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete,Greece,00302841026182,00306932607174
Labels
Monday, February 11, 2019
Propofol and isoflurane on intraoperative motor evoked potentials
Analgesia nociception index and systemic haemodynamics during anaesthetic induction and tracheal intubation
Postoperative analgesic efficacy : Low bolus dose of IP dexmedetomidine is as efficacious as IV dexmedetomidine (0.5 μg/kg) along with IP bupivacaine
Altered anatomical relationship between internal jugular vein and common carotid artery with supraglottic airway in children
Anaesthetic management of bilateral temporomandibular joint ankylosis with cervical spine fusion for total alloplastic joint replacement in a patient with ankylosing spondylitis
LETTER TO EDITOR | ||
|
Saurav, Shalendra Singh, S Kiran, Alok Jaiswal
Department of Anaesthesiologist and Critical Care, Armed Forces Medical College, Pune, Maharashtra, India
Date of Web Publication | 11-Feb-2019 |
Correspondence Address:
Dr. Shalendra Singh
Department of Anaesthesiologist and Critical Care, Armed Forces Medical College, Pune - 411 040, Maharashtra
India
Source of Support: None, Conflict of Interest: None
DOI: 10.4103/ija.IJA_573_18
How to cite this article: Saurav, Singh S, Kiran S, Jaiswal A. Anaesthetic management of bilateral temporomandibular joint ankylosis with cervical spine fusion for total alloplastic joint replacement in a patient with ankylosing spondylitis. Indian J Anaesth 2019;63:148-50 |
How to cite this URL: Saurav, Singh S, Kiran S, Jaiswal A. Anaesthetic management of bilateral temporomandibular joint ankylosis with cervical spine fusion for total alloplastic joint replacement in a patient with ankylosing spondylitis. Indian J Anaesth [serial online] 2019 [cited 2019 Feb 12];63:148-50. Available from: http://www.ijaweb.org/text.asp?2019/63/2/148/251972 |
Sir,
It is not very common to manage a patient with ankylosing spondylitis (AS) and bilateral 'temporomandibular joint' (TMJ) ankylosis with cervical spine fusion to undergo alloplastic joint replacement. However, anaesthetic management of such patients in the context of difficult airway has been described.[1] AS presents challenges to the anaesthesiologist as a consequence of potential difficult airway, cardiovascular, respiratory complications and increased risk of neurological complications. Incidence of TMJ involvement is 4–24% in AS; however, a case where bilateral TMJ ankylosis associated with cervical spine fusion and AS having undergone total alloplastic joint replacement is rare.
A 39-year-old male patient with complaint of difficulty in mouth opening for the past 18 years presented for bilateral alloplastic TMJ replacement. Airway examination revealed 6 mm of interincisor distance, grade IV Mallampati score with no lateral movement of the mandible, along with rigidity of cervical spine. Computerised tomography scan of both TMJs confirmed severe ankylosis [Figure 1]. X-ray of the cervical spine revealed fusion of the cervical spine [Figure 2]. All routine investigations including haemogram, biochemistry, chest X-ray and ECG were within normal limits. No abnormality was detected in lung function tests and arterial blood gas analysis.
Figure 1: Three-dimensional CT scan of patient showing bilateral TMJ ankylosis Click here to view |
Figure 2: Lateral view X-ray of neck showing cervical spine fusion Click here to view |
He was planned for general anaesthesia with awake fibreoptic nasal intubation which is the gold standard[2] in view of restricted mouth opening and potential loss of airway under muscle relaxant. In the operation theatre, trolley for emergency surgical tracheostomy was kept ready. All standard monitoring devices were attached and the patient was pre-medicated with inj. glycopyrrolate 0.2 mg intravenous (IV) and inj. midazolam 1 mg IV. For nasal decongestion and topical anaesthesia, xylometazoline 0.05% nasal drops (3–5 drops) were instilled and nasal packing by gauze soaked in 2% lignocaine was done. Recurrent laryngeal nerve block was performed by injecting 2 ml of 4% lignocaine after piercing the cricothyroid membrane. Mild sedation for the awake fibreoptic intubation was achieved with inj. dexmedetomidine 20 μg IV and inj. ketamine 20 mg IV. After pre-oxygenation, both nasal passages were lubricated with lubricant jelly and fibreoptic bronchoscope was passed through the left nasal passage. After manipulation, epiglottis was visualised, and with spray-as-you-go technique using 4% topical lignocaine glottis was visualised. The pre-loaded flexo-metallic cuffed endotracheal tube size 7.0 mm was gently advanced over the bronchoscope. The position of the tube was confirmed by ETCO2 and the anaesthesia was induced with inj. propofol 120 mg IV and maintained on O2, N2O, isoflurane and vecuronium. Intraoperative period was uneventful. Operating on each side of his face posed a practical problem because of the rigidity of his cervical spine, which required a bodily tilt of the operating table by 15–25° on each side. Neck support was used during anaesthesia and movements of the neck in the presence of neuromuscular blockade were restricted to avoid neurological injury. Three litres of crystalloid were infused intraoperatively with a total blood loss of 350 ml. The patient was shifted to surgical intensive care unit (SICU) with endotracheal tube in situ and maintained on assisted ventilation support in view of difficult airway and risk of airway oedema. After 12 h, the trachea was extubated uneventfully in SICU over an airway exchange catheter in view of potential difficult extubation. The same precautions regarding patient positioning and neck movement were applied at emergence, as with intubation. The patient was discharged on the seventh postoperative day.
To conclude, we successfully managed a case of AS with bilateral TMJ ankylosis having cervical spine fusion undergoing alloplastic joint replacement. It is emphasised that the prime concerns of the anaesthesiologists are to maintain a patent airway and maintain immobility of cervical spine, apart from the other anaesthetic concerns during perioperative management of such patients.
Declaration of patient consent
The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.
Financial support and sponsorship
Nil.
Conflicts of interest
There are no conflicts of interest.
References |
1. | Dave N, Sharma RK. Temporomandibular joint ankylosis in a case of ankylosing spondylitis – Anaesthetic management. Indian J Anaesth 2004;48:54-6. [Full text] |
2. |
Figures |
[Figure 1], [Figure 2]
During general anaesthesia an average adult produces 10–12 l of carbon dioxide per hour
LETTER TO EDITOR | ||
|
Unseen complication of the exhausted soda lime
Deepak Dwivedi, Saurabh Sud, Sadhan Sawhney, Shyam P Panjiyar
Department of Anesthesia and Critical Care, Command Hospital (Southern Command), Pune, Maharashtra, India
Date of Web Publication | 11-Feb-2019 |
Correspondence Address:
Dr. Saurabh Sud
Department of Anesthesia and Critical Care, Command Hospital (Southern Command) Armed Forces Medical College, Pune - 411 040, Maharashtra
India
Source of Support: None, Conflict of Interest: None
DOI: 10.4103/ija.IJA_623_18
How to cite this article: Dwivedi D, Sud S, Sawhney S, Panjiyar SP. Unseen complication of the exhausted soda lime. Indian J Anaesth 2019;63:150-1 |
How to cite this URL: Dwivedi D, Sud S, Sawhney S, Panjiyar SP. Unseen complication of the exhausted soda lime. Indian J Anaesth [serial online] 2019 [cited 2019 Feb 12];63:150-1. Available from: http://www.ijaweb.org/text.asp?2019/63/2/150/251974 |
Sir,
During general anaesthesia an average adult produces 10–12 l of carbon dioxide per hour. Ralph Waters in 1923 pioneered the use of soda lime for chemically absorbing carbon dioxide.[1] Approximately 100 g of soda lime absorbs around 26 l of carbon dioxide.[2] Soda lime by removing carbon dioxide from fresh gas flow helps in recirculating the unused gases back into the circle system. This helps in economically reducing the requirement of fresh gas flow (oxygen, nitrous, and inhalation agents), and thus decreases pollution in operation theatre. We present here reporting of an unusual incident of an excessive water collection in the soda lime canister assembly at the anaesthesia workstation.
A 56-year-old lady was administered general anaesthesia with continuous epidural analgesia for total abdominal hysterectomy. After 25 min into surgery, monitoring showed increased peak airway pressure from the baseline of 16 to 28 cm H2O and increase in end-tidal carbon dioxide (ETCO2) from the initial value of 35 to 46 mmHg with normal wave morphology of the capnogram not touching the baseline, indicating toward rebreathing. The heart rate (HR) and mean arterial pressure (MAP) showed more than 25% variation from the baseline.
At this juncture the probable causes of the increased airway pressure such as excessive tidal volume, high inspiratory flow rate, kinking of endotracheal tube, and endobronchial intubation were ruled out and patient factors such as obesity, head down position, pneumoperitoneum, tension pneumothorax, and bronchospasm were also excluded.[3] On inspection, the faulty packing of soda lime canister was observed in both upper and lower canisters with 20% of space left empty. Moreover, there was a presence of totally exhausted soda lime in the upper canister, and the lower canister was warm to touch with water levels between the outer wall of the lower canister and the inner wall of the canister assembly [Figure 1]a and [Figure 1]b. Further to this, each time when the bellows moved, it resulted in water being sucked in and out of the canister with bubbling evident in the canister assembly [[Figure 1]a and [Video 1] (online)]. The soda lime was changed and when inspected revealed completely exhausted (white) dry soda lime granules of the upper canister in comparison to wet and less exhausted lower canister soda lime granules [Figure 1]b. Following the change of soda lime, patient's peak airway pressure, ETCO2, HR, and MAP stabilised and the rest of the surgery proceeded uneventfully.
Figure 1: (a) Excessive water bubbling between the outer wall of lower soda lime canister and the inner wall of the canister assembly. (b) The exhausted dry soda lime in the upper canister and the wet soda lime in the lower canister Click here to view |
Regeneration/peaking occurs because of surface regeneration of active hydroxides at the soda lime granules surface.[4] The amount of regeneration depends on the duration of rest given to soda lime and this may be the explanation of the reappearance of the original pink color next morning in our case after its continuous use a day before the incident.
Explanation for both rebreathing leading to hypercapnia and collection of excessive water could be due to channeling, which led to nonhomogenous flow of gases that occurs due to incorrect packing of soda lime in the canister.[1] The gas as well as the moisture collected from the exhaustion of the upper canister took the path of the least resistance forming channels and bypassing majority of the soda lime granules and hence moisture was collected in large quantity by gravity into the canister assembly. Presence of the excessive moist granules led to the phenomenon called "caking," which increased the peak airway pressure in our case.[2],[5] Therefore, careful marking of the date of change on the canister alone cannot guarantee prevention of such phenomenon, but utmost vigilance, care during refilling of canister, and knowing the total duration of use of the soda lime the day before the surgery should help in preventing such incidents.
Declaration of patient consent
The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.
Financial support and sponsorship
Nil.
Conflicts of interest
There are no conflicts of interest.
References |
1. | Stolp BW, Moon RE. Sodasorb CO2 Absorbents Manual – Shearwater Research. [monograph on the internet]. Cambridge: W.R Grace and Co.- Conn; 1993. Available from: https://www.shearwater.com/wp-content/uploads/2012/08/Sodasorb_Manual.pdf. [Last cited on 2018 Aug 23]. |
2. | |
3. | |
4. | |
5. |
Figures |
[Figure 1]
Anaesthesia for tracheal reconstruction
LETTER TO EDITOR | ||
|
Anaesthesia for tracheal reconstruction – Neither a dilemma nor a catastrophe
Vaijayanti Nitin Gadre, Deoshree Bal Ramteke, Sushila Ramkishan Yadav, Esmat Gulamraza Mundrawala
Department of Anesthesiology, Grant Government Medical College, Mumbai, Maharashtra, India
Date of Web Publication | 11-Feb-2019 |
Correspondence Address:
Dr. Vaijayanti Nitin Gadre
'Sniti-11', General Jagannath Bhosale Marg, Oppo. Mantralaya, Near Sachivalaya Gymkhana, Mumbai - 400 021, Maharashtra
India
Source of Support: None, Conflict of Interest: None
DOI: 10.4103/ija.IJA_629_18
How to cite this article: Gadre VN, Ramteke DB, Yadav SR, Mundrawala EG. Anaesthesia for tracheal reconstruction – Neither a dilemma nor a catastrophe. Indian J Anaesth 2019;63:152-3 |
How to cite this URL: Gadre VN, Ramteke DB, Yadav SR, Mundrawala EG. Anaesthesia for tracheal reconstruction – Neither a dilemma nor a catastrophe. Indian J Anaesth [serial online] 2019 [cited 2019 Feb 12];63:152-3. Available from: http://www.ijaweb.org/text.asp?2019/63/2/152/251975 |
Sir,
Narrowing of trachea due to prolonged intubation, thyroid mass or cervical malignancies is known. We report a case of tracheal stenosis for proposed tracheal reconstruction.
A 21-year-old 70-kg tracheostomised male had difficulty in breathing through his 4.5-mm tracheostomy tube. He had undergone craniotomy 4 years back, had received mechanical ventilation for 15 days and was discharged after a month with a 7.5 mm tracheostomy tube. Over a period of 4 years, the trachea could not be decannulated even after repeated laser dilatation. Computerised tomography of neck showed 1.4-cm long near-complete (7 mm diameter) obliteration of trachea at C7 to T1 level. The patient was posted for anterior tracheoplasty with tibial periosteal grafting. In the operating room, difficult airway cart including additional small-sized endotracheal tubes was kept ready. The patient was positioned supine, monitors were attached and intravenous access was secured. Nebulisation was done with 2% lignocaine 1 ml for 15 min and for premedication, intravenous ondansetron 4 mg, glycopyrrolate 0.2 mg, midazolam 1 mg, hydrocortisone 100 mg and fentanyl 60 μg were given slowly. Pre-oxygenation was done with closed circuit attached to the tracheostomy tube; anaesthesia was induced with propofol 2 mg/kg and a ratio of O2:N2O was maintained at 50:50 and 2% sevoflurane was given on spontaneous-assisted ventilation. Flexible fibre-optic nasopharyngolaryngoscope was introduced through left nostril by the surgeon to study the vocal cord dynamics and rule out inter-arytenoid and subglottic fibrosis. Overhanging epiglottis was also ruled out before deciding definitive tracheal correction. For examining the sub-glottis up to carina, vecuronium 3 mg IV was given. This step helped surgeons to count total intact tracheal rings above the stoma to plan the extent of tracheal resection or trachaeoplasty with stenting. Only 10 rings were present (normal 16–18); hence, 6-cm long and 1.8-mm internal diameter stent (Montgomery T tube) was inserted to ensure optimal tracheal length. To allow surgery as well as uninterrupted ventilation at this step, laryngeal mask airway (LMA classic size 4) was inserted, cuff was inflated, ventilation was confirmed and continued via the first anaesthesia workstation. The tracheostomy tube was removed [Figure 1] and the open stoma was secured with a sterile cuffed flexo-metallic endotracheal tube (size 5). The machine end of this tube was blocked by anaesthesiologist's gloved finger to prevent leakage of ventilated gases. As and when required, this endotracheal tube was connected to a second anaesthesia workstation. Ventilation continued alternatively through distal endotracheal tube or LMA, in coordination with proximal and distal end suturing, respectively, of the stent inside the trachea.
Figure 1: Figure showing open stoma and LMA inserted Click here to view |
A horizontal incision was taken below the level of stoma, a subplatysmal flap was elevated, the strap muscles were separated and the trachea with stoma was exposed. The perpendicular end of the T-tube was cut and the longitudinal portion inserted from the lower end of the cricoid cartilage superiorly up to the first tracheal ring inferiorly. The anterior wall of the resected trachea was reconstructed with a 5-cm × 2-cm tibial periosteum graft, haemostasis was achieved and wound was closed in layers after confirming no air leak. Ventilation was controlled through the LMA throughout until closure. After return of spontaneous ventilation, reversal was done with neostigmine 0.05 mg/kg and glycopyrrolate 0.008 mg/kg. Patient was extubated and shifted to critical care for monitoring.
Anaesthesia for surgical procedures on the trachea and major airways is essentially perilous because an already compromised airway needs to be shared with the surgeon. The unique challenge is the ability to maintain adequate oxygenation and uninterrupted ventilation. A discrete plan for ventilation at each surgical step is needed. Considering the extent of tracheal pathology, preparations for alternative modes of ventilation are employed in coordination with the surgeon. In the face of an open airway, ventilation can be managed by manual oxygen through a small bore anode tube placed through the upper tracheal lesion combined with a distal endotracheal or bronchial tube inserted distal to the stenosis.[1] Earlier belief was that maximum length of the trachea that can be resected is 2 cm.[2] Lesions requiring resection of more than 6 cm or more than 50% of total length of trachea in adults or more than 30% trachea in children are considered inoperable. Longer segment involvement after previous surgery needs patch augmentation or slide trachaeoplasty.[3] Tissue engineering advances have successfully used cadaveric allografts and autologous tissue.[4]
In the present case, T-tube was appropriate to palliate the obstruction. It allowed respiration through nasopharynx, preserved humidification and speech. It has no tissue irritation and hence proved useful.
Patient was advised postoperatively to retain follow-up until complete reepithelialisation and undergo stent removal.
Meticulous preoperative planning, precise airway control and perfect coordination to oxygenate the patient with each distinct surgical step were the essence of our successful management of anaesthesia during transected airway surgery.
Declaration of patient consent
The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.
Financial support and sponsorship
Nil.
Conflicts of interest
There are no conflicts of interest.
References |
1. | |
2. | |
3. | |
4. |
Figures |
[Figure 1]
Collaboration request
Hi there How would you like to earn a 35% commission for each sale for life by selling SEO services Every website owner requires the ...
-
Media Alarms: Eating Meat Heats the Planet You may have noticed a media theme over recent months linking meat eating with climate change...
-
This is the fourth in a series of posts based upon Jordan Peterson's book Maps of Meaning, published in 1999 after 17 years of researc...